TRIG™
gasification
A circulating transport gasifier for low-rank coal and biomass, with dry feed and dry ash. Proven at commercial scale.
- Gasifier availabilityAfter initial refractory corrections
- 99.98%
- Of design syngas flowReached in operation
- 99.7%
- No burners
- No slag
- No internal moving parts
Below the ash melting point
TRIG™
899–954°C
Dry ash
No slag.
- No refractory corrosion
- No tap to block
- Higher availability
Entrained-flow gasifier
1,200–1,600°C
Molten slag
Against conventional gasifiers
| Entrained-flow | Fixed or moving bed | TRIG™ | Operating record | |
|---|---|---|---|---|
| Coal preparation | Slurry or ultra-fine powder | Sized lump coal, fines screened out | Dry, fine coal; tolerates fines | Lignite often mined above 50% moisture, fed dry |
| Operating temperature | 1,200–1,600 °C. Ash melts; burners and refractory wear. | 900–1,100 °C. Ash stays dry. | 850–975 °C. Ash stays dry; no burners. | 899–954 °C |
| By-products | Molten slag and black water | Tar left in the gas | Dry ash; tar broken down | 57,000+ t of ash discharged dry |
Operating record
First-year syngas availability ranked in the upper tier of IGCC plants worldwide.
- Commercial IGCC facility in the United States
- 582 MW
- The size of the next-largest gasifier in IGCC service
- ~2×
- Scale-up from the development unit
- 73×
- Hours on the transport reactor, at demonstration and commercial scale
- 35,000+
- Dried lignite fed to the gasifiers
- 407,000 t
- Gasifier availability by train, excluding a shop-installed refractory defect
- 99.98–100%
Process
-
Dry coal feed
Meters dried, milled coal into the pressurized gasifier
-
Gasifier
Converts coal to raw syngas in a circulating loop of hot solids
-
Syngas cooler
Cools the raw gas and raises high-pressure steam
-
Particulate control
Candle filters take fine ash out of the gas, dry
-
Ash cooling
Cools and depressurizes ash for discharge as a dry solid
Dry coal feed
Six parallel lines serve each gasifier, and four of them carry full load.
- Average moisture of the lignite as mined
- 45.5%
- Fines in weathered coal stockpiles
- ~60%
- Ash content, without slagging limits
- 30%+
- Turndown per coal feeder
- 25:1
- Highest rate run through one feeder
- 56.7 t/h
- Continuous availability of the feed system
- ~1 year
Gasifier
Dry coal feed
178.7t/h
- Slurry water
- None
- Burners
- None
Raw syngas
581.5t/h
- Carbon conversion
- 97.1–98.2%
- Cyclone collection efficiency
- 99.9%+
Solids circulation
18,100t/h
- Circulating solids to fresh coal
- 100:1
- Moving parts in the loop
- None
Coal feed range
2.3–181t/h
2.3181 t/h
- Operating pressure
- 4.8–36.2 bar(g)
- Gasification temperature
- 899–954 °C
Design targets met
At high load, a single train ran within 2% of rated throughput and converted more carbon than specified.
| Design | Achieved | Share of design | |
|---|---|---|---|
| Raw syngas | 582.9 t/h | 581.5 t/h | 99.7% |
| Clean syngas | 379.7 t/h | 375.1 t/h | 98.8% |
| Syngas heating value, LHV | 1,260 kcal/kg | 1,257 kcal/kg | 99.8% |
| Coal feed | 181.4 t/h | 178.7 t/h | 98.4% |
| Carbon conversion | 97% | 97.1–98.2% | Exceeded |
| Solids circulation | 12,700 t/h | 18,100+ t/h | 143%+ |
| Particulate at the filter outlet | <0.1 ppmw | <0.1 ppmw | Met |
Syngas cooler
Two parallel strings per gasifier raise steam at 124 bar(a), superheated above 538 °C.
- Syngas temperature across the cooler, design basis
- 950 → 316 °C
- Of design superheated-steam temperature
- 96%
- Of the steam turbine’s inlet steam, at peak
- 40%
- With minimal deposits and stable heat transfer
- 200+ days
Particulate control
Ash loading at the candle filter inlet reached 30,000 ppmw. At the filter outlet it was below 0.1 ppmw.
- Peak ash loading entering the candle filters
- 30,000 ppmw
- Leaving the candle filters
- <0.1 ppmw
Cleaner than ambient air.
- Outdoor air at the U.S. 24-hour particulate limit, 150 µg/m³
- 0.13 ppmw
- Syngas leaving the filter
- <0.1 ppmw
Ash cooling
Coarse and fine solids are let down to atmospheric pressure continuously, without lock hoppers.
- Ash cooled and discharged dry
- 57,000+ t
- Temperature drop across the primary coarse-ash cooler
- 640+ °C
- Fine-ash outlet temperature, against a 177 °C design
- ≤118 °C
- Mass-mean size of the fine ash handled
- ~10 µm
Syngas
| Expected | Actual | Share of the syngas | |
|---|---|---|---|
| H₂ | 32.0% | 31.2% | |
| CO₂ | 5.0% | 4.6% | |
| CO | 1.9% | 1.9% | |
| CH₄ | 3.0% | 3.1% |
Products
- Hydrogen
- Ammonia
- Urea
- Methanol
- DME
- SNG
- Fischer–Tropsch fuels
- Power
Capture and cleanup
CO₂ removal met or exceeded its design rate and reached pipeline specification in integrated operation.
- CO₂ capture, against a 65% design basis
- 65–75%
- Tonnes of CO₂ delivered at pipeline specification
- ~100,000
- Sulfur in the sweet syngas
- <1 ppmv
- Mercury emissions, as a share of the federal limit
- ~0.1%